Sci Rep ; 12(1): 13019, 2022 07 29.
Article in English | MEDLINE | ID: covidwho-2004796

ABSTRACT

The development of new approaches for the decontamination of surfaces is important to deal with the processes related to exposure to contaminated surfaces. Therefore, was evaluated the efficacy of a disinfection technology using ozonized water (0.7-0.9 ppm of O3) on the surfaces of garments and accessories of volunteers, aiming to reduce the spread of microbial pathogens in the workplace and community. A Log10 microbial reduction of 1.72-2.40 was observed between the surfaces tested. The microbial reductions remained above 60% on most surfaces, and this indicated that the disinfection technology was effective in microbial log reduction regardless of the type of transport used by the volunteers and/or their respective work activities. In association with the evaluation of efficacy, the analysis of the perception of use (approval percentage of 92.45%) was fundamental to consider this technology as an alternative for use as a protective barrier, in conjunction with other preventive measures against microbiological infections, allowing us to contribute to the availability of proven effective devices against the spread of infectious agents in the environment.


Subject(s)
Disinfectants , Disinfection , Disinfectants/pharmacology , Humans , Perception , Technology , Water
2.
Applied Sciences ; 12(15):7771, 2022.
Article in English | MDPI | ID: covidwho-1969075

ABSTRACT

Within the context of the coronavirus disease (COVID-19) pandemic, different disinfection technologies have been developed to efficiently exercise microbial control, especially to minimize the potential risks that are associated with transmission and infection among healthcare professionals. Thus, the aim of this work was to evaluate the perception of professionals regarding the use of a new technology (chamber) for the instantaneous decontamination of personal protective equipment before the doffing stage. This was a cross-sectional descriptive study where the study data were obtained by using a questionnaire with qualitative questions. In total, 245 professionals participated in the study in three hospitals. Healthcare professionals represented 72.24% (n = 177) of the investigated sample. Approximately 69% of the professionals considered the disinfection chamber as a safe technology, and 75.10% considered it as an important and effective protective barrier for healthcare professionals in view of its application before the doffing process. The results found in this study demonstrate that the use of spray technology in the stage prior to the doffing process is acceptable to professionals, and that it can be an important tool for ensuring the additional protection of the professionals who work directly with patients who are diagnosed with COVID-19.

3.
PLoS One ; 16(6): e0250854, 2021.
Article in English | MEDLINE | ID: covidwho-1388910

ABSTRACT

The use of personal protective equipment (PPE) has been considered the most effective way to avoid the contamination of healthcare workers by different microorganisms, including SARS-CoV-2. A spray disinfection technology (chamber) was developed, and its efficacy in instant decontamination of previously contaminated surfaces was evaluated in two exposure times. Seven test microorganisms were prepared and inoculated on the surface of seven types of PPE (respirator mask, face shield, shoe, glove, cap, safety glasses and lab coat). The tests were performed on previously contaminated PPE using a manikin with a motion device for exposure to the chamber with biocidal agent (sodium hypochlorite) for 10 and 30s. In 96.93% of the experimental conditions analyzed, the percentage reduction was >99% (the number of viable cells found on the surface ranged from 4.3x106 to <10 CFU/mL). The samples of E. faecalis collected from the glove showed the lowest percentages reduction, with 86.000 and 86.500% for exposure times of 10 and 30 s, respectively. The log10 reduction values varied between 0.85 log10 (E. faecalis at 30 s in glove surface) and 9.69 log10 (E. coli at 10 and 30 s in lab coat surface). In general, E. coli, S. aureus, C. freundii, P. mirabilis, C. albicans and C. parapsilosis showed susceptibility to the biocidal agent under the tested conditions, with >99% reduction after 10 and 30s, while E. faecalis and P. aeruginosa showed a lower susceptibility. The 30s exposure time was more effective for the inactivation of the tested microorganisms. The results show that the spray disinfection technology has the potential for instant decontamination of PPE, which can contribute to an additional barrier for infection control of healthcare workers in the hospital environment.


Subject(s)
COVID-19/prevention & control , Decontamination , Infection Control , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Protective Clothing , Respiratory Protective Devices , SARS-CoV-2 , Bacteria , Bacterial Infections/epidemiology , Bacterial Infections/prevention & control , Bacterial Infections/transmission , COVID-19/epidemiology , COVID-19/transmission , Decontamination/instrumentation , Decontamination/methods , Humans
4.
Applied Sciences ; 11(7):3081, 2021.
Article in English | MDPI | ID: covidwho-1160170

ABSTRACT

To control infectious diseases such as the severe acute respiratory syndrome coronavirus (Covid-19) that caused the current pandemic, disinfection measures are essential. Among building measures, disinfection chambers can help to decrease the transmission rate through the sanitizing capacity of the disinfectant used, which can thereby clean surfaces or humans. Out of existing biocides, ozone is considered one of the safest for humans, but one of the most powerful oxidizers, making the substance a better alternative as the biocidal solution in disinfection chambers. Analyses were carried out by using all patented documents related to disinfection chambers that used ozone as a disinfectant. A Derwent Innovation Index (DII) database search was undertaken to find these patents. Patent prospecting resulted in 620 patent documents that were divided into 134 patent families. There was no technology related to protective barriers for individuals, and the majority of patents in the retrieved data aimed at sterilizing medical devices and surfaces. Given that the specific Cooperative Patent Classification (CPC) code for ozone dissolved in liquid was used in the methodology search, but not included among the 10 most used codes in the patents, the use of ozonized water may be an innovative approach in the technology landscape of sterilization chambers.